Eemax Tankless Tankless Water Heaters
Tankless Water Heaters creates hot water on demand. So you need a
proportional amount of energy or KW to heat the flow or GPM you need for
your application. The Chart below will help you determine the correct
electric Eemax Tankless Water Heater, based on flow rate and temperture rise

 |
Item Name: Eemax Tankless EX280T2T
Item Price: $730 to $800
Gas Type: Electric
Item SKU: special prod number
|
| |
|
| Product Description |
The Eemax EX280T2T Series Three Electric
Tankless Water Heater.
Whole house unit for multiple showers. Turns on in stages, based
upon water flow rate. Equipped with microprocessing temp control
with staged heating modules.
Eemax EX280T2T Series Three Electric Tankless Water Heater
Applications:
• Engineered to turn on in stages
• Uses energy for amount of flow
• Sophisticated thermostat delivers precise outlet temperature
• Cold or Hot water feed
Eemax EX280T2T Series Three Electric Tankless Water Heater Features:
• On Demand Hot Water - no delay.
• Cut Energy Waste - flow switch activates heater only on demand (no
standby heat loss).
• Continuous Hot Water - no storage capacity to run out.
• Designed for Durability - constructed of high strength reinforced
"ENGINEERING PLASTIC"
• Ni Chrome Element - a unique, patented flow path ensures optimum
heat transfer and extended element life.
• Compact Size - dimensions 12" x 12" x 3.5"
• Reduces Calcification.
• Field Serviceable Element - replaceable cartridge element
Eemax EX280T2T Series Three Electric Tankless Water Heater
Specifications:
• Volts 240V
• KW 28.5kW
• Amps 120(3x40)A
• Rise at 2 GPM 96°F
• Rise at 3 GPM 65°F
• Rise at 4 GPM 47°F
• Wire Size AWG 8
• Dimensions 10.75" x 5.25" x 2.125"
• Weight 12 lbs
• Element - Triple replaceable Ni Chrome cartridge element inserts
• Connections: 5/8" i.d. compression (1/2" copper pipe) at bottom of
unit.
• Operating pressure minimum: 25psi
• Operating pressure maximum: 150psi
* The voltage, amperage, and circuit breaker specifications must be
met for this heater to function. Please make sure all requirements
are met before purchasing this heater. Manufacturer's start up
procedures must be observed. |
| Back to Top |
|
Parts
|
|
|
| |
|
| Product Description |
THe RTG-42 Series of water heaters
require a 3 Inch Catagory 3 Venting. |